Optician shop
Wall Washer Lens & HI Lens
Learn MoreDo not neglect the lighting of educational, because this is the most important place for school-age growth. Natural light is a good condition, but it cannot meet the indoor and outdoor needs day and night. So it needs to be equipped with a suitable solution.In the previous classrooms, most of the fluorescent tubes were hung from the ceiling, the layout was fixed, and the blackboard did not have accent lighting.Now, different lighting can be arranged flexibly for different places, reports, class discussions, meetings, and sports can be arranged according to different requirements.
According to research, lighting can help focus on learning and stimulate brain thinking. LED lighting has a good green energy, environment and saves power.In addition to being eco-friendly, low-glare products are beneficial to the human health, making the vision less stimulating, sober, improving learning ability, inspiring people, and stabilizing the learning mood of students.You also need to pay attention to details, such as work surface uniformity, ceiling height, orientation, comfort, etc., which is all important.To create the best lighting solutions to educational institution, so that students are healthy and strong, lighting is no longer just to provide lighting.
Insufficient or uneven illumination may result in slower reading speed, inattention, poor posture, and thus effect vision.We hope to create a high-quality lighting environment to improve student comfort and reduce eye fatigue.The correct lighting should make students more comfortable with the daily learning environment and easier to stay focused.
Classroom dimensions:8*8*4 m
Product family:Low Glare 3R Lens
Application:Desk
Part number:CKO-MX16-286061-3307
Luminaire mounting height:4 m
Average illuminance of working surface:644 lx
Illumination uniformity of working surface:79%
Product family:Low Glare 3R Lens
Application:Blackboard
Part number:CKO-MX16-286061-3309
Luminaire mounting height:3.2 m
Average illuminance of working surface:878 lx
Illumination uniformity of working surface:61%
In childhood, the activity is vigorous, the vision is developing, the whole space should be bright, and the bright light can guide the children to study at the table.When taking a nap, indirect lighting can be used to reduce the fear and insecurity of the dark and cultivate good sleeping habits.
Kindergarten dimensions:6*6*3 m
Product family:Low Glare High Intensity Lens
Application:Table
Part number:CKO-CH15-075033-4460
Luminaire mounting height:3 m
Average illuminance of working surface:743 lx
Illumination uniformity of working surface:85%
Product family:Linear Light Lens
Application:Ceiling
Part number:CKO-M818-120020-1008
Luminaire mounting height:2.8 m
Luminaire can illuminate both sides of the wall. Considering that the bulletin and locker storage will not be unclear due to the dimness. Good lighting can guide the direction of the area that will pass through during and after class.
Corridors dimensions:Width 3 m, Height 3 m
Product family:Wall Washer Biaxial Optical Tilt 26°
Part number:CKO-CB19-075026-2030
Luminaire mounting height:3 m
Average illuminance of working surface:563 lx
Illumination uniformity of working surface:53%
The library is divided into areas for book storage and reading, so the luminaire are different. The bookshelf area needs to illuminate the bookshelves sufficiently and evenly to make searching for books easier and faster. The table illumination in the reading area should be even and comfortable, so that regular reading will not cause discomfort. The sofa area focuses on lighting, giving people a inspired atmosphere.
Library dimensions:10*10*3.5 m
Product family:Wall Washer Optical Tilt 20°
Application:Bookshelf
Part number:CKO-CW18-075026-0321
Luminaire mounting height:3 m
Average illuminance of working surface:874 lx
Illumination uniformity of working surface:68%
Product family:Soft Shading Oval Lens
Application:Bookshelf
Part number:CKO-SA15-075033-4009
Luminaire mounting height:3 m
Average illuminance of working surface:673 lx
Illumination uniformity of working surface:51%
Library dimensions:10*10*3.5 m
Product family:Low Glare 3R Lens
Application:Reading area
Part number:CKO-MX16-286061-3307
Luminaire mounting height:3.5 m
Average illuminance of working surface:660 lx
Illumination uniformity of working surface:77%
Product family:Low Glare High Intensity Lens
Application:Sofa area
Part number:CKO-CH15-075033-4407
Luminaire mounting height:3.5 m
Average illuminance of working surface:797 lx
Illumination uniformity of working surface:80%
The podium should be illuminated with a focus to make the audience focus on the podium. Wall washer optical tilt 5° lens is used for the wall here, and the front half of the podium is illuminated with HI-Plus. Use products that can fit high ceilings, have sufficient central illumination, and have low glare. The audience seating area needs to provide good light and high-light comfort lighting so that the audience can get the best experience.
Lecture hall dimensions:25*20*8 m
Product family:Ultra Low Glare High Intensity-Plus Lens
Application:Auditorium
Part number:CKO-CH17-075041-0303
Luminaire mounting height:8 m
Product family:Wall Washer Optical Tilt 5°
Application:Platform
Part number:CKO-CW15-075033-4021
Luminaire mounting height:8 m
The stadium needs the overall flux, whether it is a teammate or an opponent, it can be seen clearly, even if sweating does not affect the eyesight, the vertical illumination is uniform and sufficient illumination has certain requirements.
Sports hall dimensions:30*60*10 m
Product family:Linear Light Lens
Part number:CKO-M818-120020-1003
Luminaire mounting height:8 m
Average illuminance of working surface:960 lx
Illumination uniformity of working surface:80%
Both the buffet table and the din area are long tables, suitable for oval beam lighting, which can provide sufficient lighting for the din table without wasting light sources.
Canteen dimensions:8*15*3 m
Product family:Low Glare High Intensity Oval Lens
Application:Table
Part number:CKO-CH15-045021-1670
Luminaire mounting height:3 m
Average illuminance of working surface:692 lx
Illumination uniformity of working surface:69%
The outdoor lighting of the school has an important function to protect the safety of teachers and students on the campus at night . Not only that , the use of light to present architectural details , so that the building is perfectly integrated with the surrounding environment , is also a feature of outdoor lighting .For example , parking areas , aisles , entrance and exit gates , rest areas , exterior walls , benches , gardens , all needs lighting .It will not make people feel insecure because it is too dim.
Product family:Street Light Lens
Application:Campus entrance
Part number:CKO-TM17-163062-0660
Luminaire mounting height:6.5 m
Part number:CKO-TM17-163062-0630
Application:Bike Parking area
Luminaire mounting height:6 m
Product family:Ultra Low Glare High Intensity-Plus Lens
Application: Up & Down Wall Light
Part number:CKO-CH17-045026-0401
Luminaire mounting height:4.5 m
Product family:Wall Washer Optical Tilt 5°
Application: Underground Light
Part number:CKO-CW15-060027-4221
Luminaire mounting height:0 m
Product family:Street Light Lens
Application: School Grounds
Part number:CKO-TM17-163062-0601
Luminaire mounting height:6 m
The website uses the Dialux simulation effect. If you want to know more about the product's performance, please contact our company, and we will provide you with a suitable solution. For more applications, please refer to other units.